70 VERSA SATEL
In the TELIM format, events can only be sent via the analog telephone line.
Telephone
Telephone no. – telephone number of the monitoring station.
Repetitions the number of attempts to send an event code via the telephone line. If all
attempts fail, the control panel will suspend reporting via the telephone line. Up to 31
retries can be programmed. Programming the value 0 means that monitoring will be
suspended after 8 attempts.
Suspend time – the time for which reporting will be suspended, if attempts fail to send an
event code through all provided transmission paths. The control panel will resume the
attempt of establishing telephone connection with the monitoring station after this time
expires or a next, new event occurs. Up to 30 minutes can be programmed. Programming
the value 0 means that an attempt to establish telephone connection with the monitoring
station will only be taken after occurrence of a new event in the system.
ETHM
Server address – network address of the monitoring station for reporting via Ethernet or.
You can enter either the IP address or the domain name.
Port – number of port used for communication between the control panel and the monitoring
station. You can enter a value from 1 to 65535.
Station key – a string of up to 12 alphanumeric characters (digits, letters and special
characters), which is used for encryption of data sent to the monitoring station.
ETHM key – a string of up to 5 alphanumeric characters to be used for identification of the
control panel for the purposes of reporting via Ethernet.
Identifiers
Event codes are sent to the monitoring station with one of the four identifiers:
identifier 1 – events from zones (alarms, tampers, troubles),
identifier 2 – alarms triggered from keypad, arming/disarming by means of zones, quick
arming, loss of communication with wireless devices, as well as expander troubles
and tampers,
identifier 3 – arming/disarming and alarm clearing by means of code or proximity card,
system identifier – power supply troubles, zone bypasses, troubles of control panel high-
current outputs, communication bus trouble, programming related events, etc.
The identifier consists of 4 hexadecimal characters (digits or letters from A to F). Entering the
value 0000 means that events assigned to that identifier will not be reported. Using the digit 0
in the identifiers is not recommended.
SIA / TELIM prefix – 2 characters which will precede each of the identifiers in case of the
SIA and TELIM formats. Thus an identifier consisting of 6 characters can be obtained. 2
hexadecimal characters (digits or letters from A to F) can be programmed. Entering 00
means that the prefix will not be added. Using the digit 0 in the prefix is not recommended.
Station 1 options / Station 2 options
SIA – send part. name – if the option is enabled, in the SIA format, the name of partition
where the event took place will also be sent, in addition to the event code.
SIA – send source name – if the option is enabled, in the SIA format, the name of event
source (zone, user, etc.) will also be sent, in addition to the event code.
SIA – confirm each block – if the option is enabled, the control panel will wait for
acknowledgement by the monitoring station of receiving every data block sent in the SIA
format. The option applies to telephone reporting.