SATEL VERSA 45
– 21. DETECTORS RESETTING – the output activates for a preset time, when the arming
procedure is initiated in the selected partition (without taking into account the exit delay).
The users authorized to access the given partition can activate the output by using the
OUTPUTS RESET function.
Reset in partition 1 / Reset in partition 2 – depending on the output function:
– 11. FIRE DETECTORS POWER SUPPLY – the users having access to the selected partition
can deactivate the output for 16 seconds by means of the OUTPUTS RESET user function,
– 14. CHIME, for which the CUT-OFF TIME equal to 0 has been programmed – the users
having access to the selected partition can deactivate the output by means of the
OUTPUTS RESET user function.
Pulse – output with pulsating mode of operation (0.5/0.5 sec.). This option refers to the
outputs for which the cut-off time is to be programmed (except for the 1. EXTERNAL SIREN
and 2. INTERNAL SIREN outputs), and outputs with the 17. EXIT DELAY STATUS, 18. ARMED
STATUS
, 19. TROUBLE STATUS and 22. ETHM TROUBLE STATUS functions.
Polarity +12V – sets the output operating mode. If the option is disabled, the output is
inverted.
“–” terminal of high-current output / low-current output
option enabled
(normal polarity)
option disabled
(reverse polarity)
active state
shorted to ground disconnected from ground
inactive state
disconnected from ground shorted to ground
Table 6. Mode of output operation depending on the POLARITY +12V option.
Fire alarms sign. – option for the 1. EXTERNAL SIREN and 2. INTERNAL SIREN outputs. The
output signals in pulsating mode the fire alarms from selected zones (see: ACTIVATION:
ZONES
) and partitions (see: ALARM SIGNALING PARTITION 1 and ALARM SIGNALING
PARTITION
2 output options).
One partition sign. – option for the 18. ARMED STATUS and 20. ALARM/ARM STATUS outputs.
The output indicates armed mode when any of the two partitions is armed (if the option is
disabled, only when both partitions are armed).
Arm/Disarm/Clear sign. – option for the 1. EXTERNAL SIREN and 2. INTERNAL SIREN outputs
(see also: C
LEARING FROM PART. 1 and CLEARING FROM PART. 2 output options and
A
RM./DISARM./CLEAR. SIGNALING FROM ZONES ONLY global option). The output signals:
starting the arming procedure (which is equivalent to arming if no exit delay has been
programmed) – 1 tone,
disarming – 2 tones,
alarm clearing – 4 tones,
denial of arming or arming procedure failure (see: PREVENT ARMING IF NOT READY global
option or GRADE 2 global option) – 7 tones.
Tone duration is about 0.3 second.
Alarm signaling – part. 1 / Alarm signaling – part. 2 – an option for the alarm outputs. The
output signals the selected partition alarms which were not triggered by zones.
Timer 1 / Timer 2 / Timer 3 / Timer 4 – options for the 15. CONTROLLED outputs. The output
is controlled by selected timer (if timer status changes to “ON", the output will be activated
for the CUT-OFF TIME).
Mainboard TMP input – an option for the 1. EXTERNAL SIREN, 2. INTERNAL SIREN and
10. T
AMPER ALARM outputs. The output will be activated by the mainboard tamper (violation
of the mainboard TMP zone).