Parameters
BV-H2464GB, 1234
- 94 -
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
P17.03 DO: Scale Start
Default: DO VCU1.DI15 High
Alternative: DO
n/a
Sends a start command to the feeder's main drive.
P17.04 DO: Actual Flow Rate MIN
Default: DO VCU1.DI12 Low
Alternative: DO
n/a
The output signal becomes active if the feed rate falls below the minimum feed rate (P06.01
Limit: Actual Flow Rate MIN).
The contact output is independent of the event class.
P17.05 DO: Actual Flow Rate MAX
Default: DO VCU1.DI10 Low
Alternative: DO
n/a
The output signal becomes active when the maximum feed rate (P06.03 Limit: Actual Flow
Rate MAX) is exceeded.
The contact output is independent of the event class.
P17.06 DO: Load MIN
Default: n/a
Alternative: n/a
DO
P17.07 DO: Load MAX
Default: n/a
Alternative: n/a
DO
P17.08 DO: Speed MIN
Default: n/a
Alternative: n/a
DO
P17.09 DO: Speed MAX
Default: n/a
Alternative: n/a
DO