Parameters
BV-H2464GB, 1234
- 84 -
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
13.3.2.13
13.3.2.1313.3.2.13
13.3.2.13
Parameter Block
Parameter BlockParameter Block
Parameter Block
13
1313
13
-
--
-
Belt Monitoring
Belt MonitoringBelt Monitoring
Belt Monitoring
P13.01 VAP Active
Default: NO
Alternative: NO
YES
Activates the delay for the belt load used for regulation for the time required for the material
to reach the discharge point.
P13.02 Platform Dis.Length
Default: 0 % LB
Min: 0 % LB Max: 50 % LB
The space from the middle of the weighbridge to the material discharge in % of the entire
belt length (refer to P04.06 Belt Circuit No.)
P13.03 Belt Sensor Active
Default: NO
Alternative: NO
YES
The belt sensor and sensor surface in the conveyor belt are used for identifying Belt Drift
and Slip Value and synchronizing adaptive belt influence compensation (BIC).
The belt sensor must be activated and the signal input defined in order to apply adaptive
belt influence compensation (P13.05 BIC Active), basic slip control (P13.14 Event: Slip) and
basic belt motion monitoring (4504).
P13.04 DI: Source Belt Sensor
Default: DI VCU1.DI4 High
Alternative: DI
n/a
P13.05 BIC Active
Default: NO
Alternative: NO
YES
Automatic belt influence compensation (BIC) monitors and corrects the belt influence. As
with belt monitoring it requires a sensor and sensor surface.
Note:
Initial startup is made without active BIC.
Characteristics:
After belt influence compensation is activated the influence that the conveyor belt has on
weight measurement is offset after approximately ten belt circuits.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Intecont Tersus Beltweigher and is the answer not in the manual?

Schenck process Intecont Tersus Beltweigher Specifications

General IconGeneral
BrandSchenck process
ModelIntecont Tersus Beltweigher
CategoryControl Panel
LanguageEnglish

Related product manuals