Parameters
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
BV-H2464GB, 1234
- 69 -
P04.03 Total Tare
Default: 0 kg/m
Min: 0 kg/m Max: 10000 kg/m
Total Tare = Basic Tare + Tare Correction
P04.04 Basic Tare
Default: 0 kg/m
Min: 0 kg/m Max: 10000 kg/m
Results of the 'Tare' adjustment program corresponding to the dead load on an empty belt.
P04.05 Tare Correction
Default: 0 kg/m
Min: -1000 kg/m Max: 1000 kg/m
Results of the >0< Zero Set adjustment program or automatic zero setting.
P04.06 Belt Circuit No.
Default: 1000000 I/B
Min: 0 I/B Max: 9000000 I/B
Number of impulses from the pulse generator at the belt drive that constitute one belt rota-
tion.
Results of the LB: Pulses/Belt adjustment program. Sets the duration of adjustment pro-
grams.
Divided by P02.04 Pulses per length this results in the length of the belt in m.
13.3.2.5
13.3.2.513.3.2.5
13.3.2.5
Parameter Block
Parameter BlockParameter Block
Parameter Block
05
0505
05
-
--
-
Analog Outputs
Analog OutputsAnalog Outputs
Analog Outputs
The parameters in this group select the control source for the analog output channels. On the VCU 20104
controller only one analog channel is available and it is set to feedrate feedback by default.
P05.01 AO: Actual Flow Rate
Default: AO VCU1.DO4
Alternative: AO
n/a
Analog output channel for the actual feed rate.
Also refer to: P05.02 Flow Rate Offset, P05.03 Flow Rate Range
P05.02 Flow Rate Offset
Default: 4 mA
Min: -200 mA Max: 200 mA
Output current for an actual feed rate value of 0%.
Reference: P02.02 Nominal Flow Rate
Also refer to: P05.01 AO: Actual Flow Rate