Events
BV-H2464GB, 1234
- 116 -
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
HI03 Event: Load MAX
(P06.08)
The belt load is greater than the maximum value set in P06.07 Limit: Load MAX
Possible causes:
- bulk material shooting out of the discharge chute
- disturbance forces from force shunts or pressures acting on the weighing equip-
ment
HI04 Event: Speed MAX
(P06.12)
The belt speed is greater than the maximum value set in Limit: Speed MAX
15.1.7
15.1.715.1.7
15.1.7
Event Group:
Event Group:Event Group:
Event Group:
Mechanic
MechanicMechanic
Mechanic
WM02 Event: Slip
(P13.14)
This event is identified if the belt motion does not correspond to that predicted by the
motor revolutions.
Possible causes:
- belt is slipping at the drive pulley
- withdrawal forces are too high
- gearing is defective
- belt or drive pulley heavily soiled
Steps:
- visual inspection of the belt and the bulk material flow
WM03 Event: Belt Skew
(P13.12)
Belt has run off-center. Feeder is no longer operable.
Action: See Event: Belt Drift
Related threshold: Belt Skew
WM04 Event: Belt Drift
(P13.10)
The belt has exceeded the tolerance levels set.
Steps:
1. Remove any soiling to the tail and drive pulleys
2. Align the belt
Monitoring may also be subject to error. Therefore: keep an eye on the service value
for the belt motion sensor and correct any errors that may arise.
Related threshold value: Belt Drift