Parameters
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
BV-H2464GB, 1234
- 93 -
P16.06 DI: External Event 1
Default: n/a
Alternative: n/a
DI
Input 1 for an external interference signal.
The input is also linked to the internal interference logic (block: interlocking).
Also refer to: P14.11 Event: External Event 1
P16.07 DI: External Event 2
Default: n/a
Alternative: n/a
DI
Input 2 for an external interference signal.
P16.08 DI: Reset Totalizer 1
Default: n/a
Alternative: n/a
DI
Digital input for canceling totalizing counter 1. The positive flank is the actuator.
P16.09 DI: Reset Totalizer 2
Default: n/a
Alternative: n/a
DI
Digital input for clearing totalizing counter 2. The positive flank takes effect.
13.3.2.17
13.3.2.1713.3.2.17
13.3.2.17
Parameter Block
Parameter BlockParameter Block
Parameter Block
17
1717
17
-
--
-
Digital Outputs
Digital OutputsDigital Outputs
Digital Outputs
The parameters in this group are used to associate various controller functions with specific digital output
channels. Most of the functions specified in this group are hard wired at assembly.
P17.01 DO: ALARM
Default: DO VCU1.DI11 Low
Alternative: DO
n/a
The output becomes active if any alarm is triggered (common alarm). The scales have
failed.
P17.02 DO: Start Prefeeder
Default: DO VCU1.DI14 High
Alternative: DO
n/a
The digital output for turning the prefeeder on or off.