Parameters
BV-H2464GB, 1234
- 82 -
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
13.3.2.11
13.3.2.1113.3.2.11
13.3.2.11
Parameter Block
Parameter BlockParameter Block
Parameter Block
11
1111
11
-
--
-
Maintenance interval
Maintenance intervalMaintenance interval
Maintenance interval
The parameters of this group define maintenance intervals and the internal accuracy analysis function.
P11.01 Maintenance Electric
Default: 3000 h
Min: 1 h Max: 10000 h
Indication of maintenance work that may need to be performed, dependent on the duty
cycle of the power supply. This parameter defines the interval between maintenance work.
Also refer to: P11.02 Event: Maint. Electric
P11.02 Event: Maint. Electric
Default: W1
Event Group: SC Number: 03
The sum of the times during which the mains voltage is on is greater than the time P11.01
Maintenance Electric.
A message occurs after each expired time interval. The message may indicate service work
required.
P11.03 Maintenance Feeder Run
Default: 3000 h
Min: 1 h Max: 10000 h
Indication of maintenance work that may need to be performed, dependent on the duty
cycle of the scales (scales ON). This parameter defines the interval between maintenance
work.
Also refer to: P11.04 Event: Maint.Feeder Run
P11.04 Event: Maint.Feeder Run
Default: W1
Event Group: SC Number: 04
The sum of the runtimes of the conveying elements is greater than the time P11.03 Main-
tenance Feeder Run.
A message occurs after each expired time interval. The message may indicate service work
required.