Calibration
CA01 Event: Error LC Input
(P14.06)
The load cell cable is improperly connected, not connected or has been interrupted.
The load cell may be faulty.
Steps to take:
- check the cabling and the load cell
- check the load cell
Note:
The power supply must be switched off and on again if the scales still cannot be
switched on even after the error has been rectified.
CA02 Event: Tachometer Input
(P14.03)
The signals at the feeder drive's impulse speedometer input are outside of the speci-
fied range.
Possible causes:
- there is a fault in the speed impulse sensor cable (check the shielding and the wir-
ing).
- the sensor has been incorrectly calibrated
CA05 Event: Linearization Error
(P15.10)
Not a monotonically increasing curve.
A monotonically increasing compensation curve is monitored when:
- linearization is switched on,
- a parameter is altered
CA06 Event: Tare Correction
(P08.05)
This event is identified if the change in tare identified by the automatic zeroing sys-
tem exceeds the threshold value in P08.04 Zeroing Limit.
Possible causes:
- low quantities of bulk material on the belt
- error in the weighing mechanics
Steps:
- visual inspection of the belt and the weighing system.
- run the base tare adjustment program
- check weight measuring using test weights

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Intecont Tersus Beltweigher and is the answer not in the manual?

Schenck process Intecont Tersus Beltweigher Specifications

General IconGeneral
BrandSchenck process
ModelIntecont Tersus Beltweigher
CategoryControl Panel
LanguageEnglish

Related product manuals