Parameters
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
BV-H2464GB, 1234
- 67 -
P02.12 Totalizer Increment
Default: 10 kg
Min: 0 kg Max: 100000 kg
Weight equivalent of an impulse at the output for the external counter as per P02.11 DO:
Pulse Counter.
The DO: Pulse Counter is blocked when setting the valence 0.
P02.13 Z1-Numberstep
Default: Automatic
Alternative: Automatic
2 kg
5 kg
20 kg
50 kg
200 kg
500 kg
0.02 t
0.05 t
0.2 t
0.5 t
Determines the increment value for counter 1 and all batch values. Parameter P02.07
Counter 1 Unit applies for "Automatic".
The increment value only applies to the local display and for printouts.
13.3.2.3
13.3.2.313.3.2.3
13.3.2.3
Parameter Block
Parameter BlockParameter Block
Parameter Block
03
0303
03
-
--
-
Calibration Data
Calibration DataCalibration Data
Calibration Data
P03.01 Belt Circuit No.
Default: 1
Min: 1 Max: 100
Sets the runtime of the programs zero, tare and weight check. Does not apply for the auto-
matic zero setting device.
P03.02 Belt Circuit Time
Default: 30 s
Min: 1 s Max: 9999 s
Determines the measurement period for the impulse/belt circuit calibration program.
Usually, the time chosen is the time required for one belt circuit.
P03.03 LC Characteristic Value
Default: 2.85 mV/V
Min: 0.01 mV/V Max: 9.9999 mV/V
Characteristic value (transmission factor) of the (main) load cell.
P03.04 LC Rated Capacity
Default: 220 kg
Min: 0.5 kg Max: 220000 kg
The total of the load cell rated loads for recording the weight of the continuous scale.