EasyManuals Logo

Schenck process Intecont Tersus Beltweigher User Manual

Schenck process Intecont Tersus Beltweigher
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
Parameters
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
BV-H2464GB, 1234
- 67 -
P02.12 Totalizer Increment
Default: 10 kg
Min: 0 kg Max: 100000 kg
Weight equivalent of an impulse at the output for the external counter as per P02.11 DO:
Pulse Counter.
The DO: Pulse Counter is blocked when setting the valence 0.
P02.13 Z1-Numberstep
Default: Automatic
Alternative: Automatic
2 kg
5 kg
20 kg
50 kg
200 kg
500 kg
0.02 t
0.05 t
0.2 t
0.5 t
Determines the increment value for counter 1 and all batch values. Parameter P02.07
Counter 1 Unit applies for "Automatic".
The increment value only applies to the local display and for printouts.
13.3.2.3
13.3.2.313.3.2.3
13.3.2.3
Parameter Block
Parameter BlockParameter Block
Parameter Block
03
0303
03
-
--
-
Calibration Data
Calibration DataCalibration Data
Calibration Data
P03.01 Belt Circuit No.
Default: 1
Min: 1 Max: 100
Sets the runtime of the programs zero, tare and weight check. Does not apply for the auto-
matic zero setting device.
P03.02 Belt Circuit Time
Default: 30 s
Min: 1 s Max: 9999 s
Determines the measurement period for the impulse/belt circuit calibration program.
Usually, the time chosen is the time required for one belt circuit.
P03.03 LC Characteristic Value
Default: 2.85 mV/V
Min: 0.01 mV/V Max: 9.9999 mV/V
Characteristic value (transmission factor) of the (main) load cell.
P03.04 LC Rated Capacity
Default: 220 kg
Min: 0.5 kg Max: 220000 kg
The total of the load cell rated loads for recording the weight of the continuous scale.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Intecont Tersus Beltweigher and is the answer not in the manual?

Schenck process Intecont Tersus Beltweigher Specifications

General IconGeneral
BrandSchenck process
ModelIntecont Tersus Beltweigher
CategoryControl Panel
LanguageEnglish

Related product manuals