Parameters
BV-H2464GB, 1234
- 68 -
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
P03.05 Effective Platform Length
Default: 1 m
Min: 0.1 m Max: 50 m
Effective (active) length of the weighing platform. In systems with a weighing roller that
rotates in the direction of belt travel, the active length is half of the distance between the
non-weighing rollers on either side of the weighing roller.
P03.06 Lever Ratio
Default: 1
Min: 0.01 Max: 2
Lever transmission between the force application at the weighing section and the force on
the load cell. For scales that use levers for the application of force to the load cell, this sets
the ratio between the weight and the force acting on the load cell.
P03.07 Angle
Default: 0 Grad
Min: 0 Grad Max: 60 Grad
The inclination of the longitudinal axis to the horizontal axis of the scales with the load cell
installed vertical to the belt.
P03.08 Calibration Weight
Default: 50 kg
Min: 0.001 kg Max: 22000 kg
Belt load measurement can be verified using test weights. This is done by running
the adjustment program CW: Span Calibrationwith an empty belt.
The test weight as it acts on the load cell is keyed in.
Also refer to: P04.02 Range Correction
13.3.2.4
13.3.2.413.3.2.4
13.3.2.4
Parameter Block
Parameter BlockParameter Block
Parameter Block
04
0404
04
-
--
-
Calibrat. Results
Calibrat. ResultsCalibrat. Results
Calibrat. Results
P04.01 Nominal Belt Load
Default: 111.11 kg/m
Min: 0.06 kg/m Max: 10000 kg/m
Reference for limit values and zeroing program.
This is calculated from Nominal Flow Rate P02.02 and Nominal Speed P02.05.
P04.02 Range Correction
Default: 1
Min: 0.5 Max: 2
The parameter affects the load measurement F proportionally.
Q(corrected) = Q(measured) * P04.02