Parameters
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
BV-H2464GB, 1234
- 101 -
P19.22 Access Rights Limitation FB
Default: NO
Alternative: NO
FIRST WRITE
REMOTE IP
Determines for network protocol Modbus-TCP which master system may intervene as a
controller:
NO: No restrictions
FIRST WRITE: The subscriber that transmits the first write access gets the control rights.
The other subscribers may read only.
REMOTE IP: Control commands from the subscriber with the IP address given in P19.23
Remote IP Address FB only will be carried out.
P19.23 Remote IP Address FB
Default: 192.168.240.250
IP address of the subscriber with control rights for Modbus-TCP.
Also refer to: P19.22 Access Rights Limitation FB
13.3.2.20
13.3.2.2013.3.2.20
13.3.2.20
Paramete
ParameteParamete
Parameter Block
r Blockr Block
r Block
20
2020
20
-
--
-
Fixed mode configuration
Fixed mode configurationFixed mode configuration
Fixed mode configuration
Configuration of the data in fieldbus communication 'FIXED' mode that were exchanged with the host com-
puter via serial interface.
Also refer to: P19.09 Configuration
P20.01 ID Preset Value 1
Default: 320
Selecting the first control command with ID 320 (decimal) in the Fieldbus telegram.
The other values can be configured as per the ID list in the Data Communication manual.
P20.02 ID Preset Value 2
Default: 352
Corresponds to P20.01 ID Preset Value 1
P20.03 ID Preset Value 3
Default: 384
Corresponds to P20.01 ID Preset Value 1