Parameters
BV-H2464GB, 1234
- 100 -
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
P19.17 Compatiblity INTECONT
Default: NO
Alternative: NO
YES
Compatibility to earlier PROFIBUS-Versions of INTECONT PLUS.
Relevant for replacement by INTECONT Tersus.
YES: Ident-No. 0524 is valid and GSD-file of INTECONT PLUS has to be used.
NO: Ident-No. 0C9B is valid and GSD-file of INTECONT Tersus has to be used.
P19.18 Identifier format
Default: BYTE
Alternative: BYTE
WORD
The configuration bytes correspond to INTECONT PLUS if the parameter is on bytes. Oth-
erwise, the data are written in words. Consistency always refers to a data word or double
data word.
This parameter together with P19.19 PA32 compatible guarantees that there is no problem
exchanging with PROFIBUS Master in an existing system without having to adapt Master.
P19.19 PA32 compatible
Default: NO
Alternative: NO
YES
YES: It is filled with ZERO bytes to 32 bytes with a defined data scope <32 bytes
P19.20 Address
Default: 63
Min: 0 Max: 63
Address of the weighing electronics at the DeviceNet.
P19.21 Baud rate
Default: 125K
Alternative: 125K
250K
500K
Data transfer rate of the DeviceNet.