EasyManuals Logo

Schenck process Intecont Tersus Beltweigher User Manual

Schenck process Intecont Tersus Beltweigher
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Parameters
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
BV-H2464GB, 1234
- 99 -
P19.12 Baud rate
Default: 9600
Alternative: 2400
4800
9600
19200
38400
Data transfer rate at Modbus-RTU.
P19.13 Data Format
Default: 8-O-1
Alternative: 8-O-1
8-E-1
8-N-1
Modbus-RTU always uses an 11-bit character frame.
Example: 8-O-1 means:
1 start bit, 8 data bit, odd parity, 1 stop bit
N = no parity, E = even parity)
P19.14 Physics
Default: RS232
Alternative: RS485-2-wire
RS485-4-wire
RS232
Selects the electrical interface type. (Modbus RTU)
P19.15 Address
Default: 16
Min: 0 Max: 126
The address of the slave at the PROFIBUS.
P19.16 FLOAT-Format
Default: IEEE
Alternative: IEEE
SIEMENS-KG
Information on the formats for all setpoints, measuring values and floating point parame-
ters.