Mode functions
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
BV-H2464GB, 1234
- 25 -
7
77
7
Mode functions
Mode functionsMode functions
Mode functions
There are functions brought together in the Mode menu for switching over into various operating modes.
Functions: Mode
Start Keyboard Mode /
Stop Keyboard Mode
Stop Prefeeder /
Particip. Prefeeder
Start Simulation /
Stop Simulation
Mode
7.1
7.17.1
7.1
Keyboard operation ON/OFF
Keyboard operation ON/OFFKeyboard operation ON/OFF
Keyboard operation ON/OFF
The Start Keyboard Mode function can be used to switch the preselected operating sources for turning
on/off and specifying the setpoint and target batching values to the INTECONT keyboard .
Stop Keyboard Mode will again select the previous sources.
The on-off status and setpoints will be retained when switching to the keyboard from an external source
(e.g. serial). The external signals are effective when switching in the opposite direction.
Display:
One part of the actual value display in the upper display area is the line containing information on the status
and process of the program. Here OP signifies that OP Mode is active.
7.2
7.27.2
7.2
Prefeeder
PrefeederPrefeeder
Prefeeder
The Particip. Prefeeder or Stop Prefeeder functions determine the impact of INTECONT on the prefeeder.
This function is activated in normal operation and INTECONT takes on controlling the prefeeder. The ma-
terial flow is interrupted when it is off and the scale can be tared, etc.
7.3
7.37.3
7.3
Simulation
SimulationSimulation
Simulation
In simulation mode, all functions of the scales can be tested without material during start-up. The scales
cannot be used for normal operation during simulation.