Parameters
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
BV-H2464GB, 1234
- 87 -
P13.17 DO: Belt Slip
Default: n/a
Alternative: n/a
DO
The digital output to show Event: Slip.
Also refer to P13.13 Slip Value
The output operates independently of the event class of the corresponding event.
P13.18 DI: BIC freeze
Default: n/a
Alternative: n/a
DI
FB
The BIC values currently running in are frozen when this digital input is set.
This prevents the values already ascertained from being falsified on belt loads that fluctuate
greatly.
13.3.2.14
13.3.2.1413.3.2.14
13.3.2.14
Parameter Bl
Parameter BlParameter Bl
Parameter Block
ockock
ock
14
1414
14
-
--
-
Events
EventsEvents
Events
P14.01 Event: Power Failure
Default: A
Event Group: WE Number: 01
This event is identified once the power supply is restored.
The scales will not switch on automatically, regardless of the event class. The event must
first be acknowledged and the command to start given again before the scales will restart.
P14.02 Event: Memory
Default: A
Event Group: SY Number: 01
The program and parameters memory are checked cyclically. An error has occurred during
that. The scales will no longer function correctly.
Steps to take:
- load the factory settings
- Normally the hardware has to be replaced.