Events
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
BV-H2464GB, 1234
- 117 -
15.1.8
15.1.815.1.8
15.1.8
Event Group:
Event Group:Event Group:
Event Group:
MIN
MINMIN
MIN
LO01 Event: LC Input < MIN
(P14.09)
The load cell load is less than 3 % of the sum of the load cell nominal loads.
Possible causes:
- force shunts or pressure ratios can reduce significantly the load on the load cell
- incorrect cabling
- faulty load cell
LO02 Event: Actual Flow Rate MIN
(P06.02)
The actual feed rate is lower than the minimum value Limit: Actual Flow Rate MIN.
Possible causes:
- no bulk material
- disturbance forces from force shunts or pressures acting on the weighing equip-
ment
- feed rate setpoint too low
LO03 Event: Load MIN
(P06.06)
The belt load is less than the minimum value set in Limit: Load MIN
Possible causes:
- no bulk material
- disturbance forces from force shunts or pressures acting on the weighing equip-
ment
LO04 Event: Speed MIN
(P06.10)
The belt speed is less than the minimum value set in Limit: Speed MIN
15.1.9
15.1.915.1.9
15.1.9
Event Group:
Event Group:Event Group:
Event Group:
Seque
SequeSeque
Sequence Monitoring
nce Monitoringnce Monitoring
nce Monitoring
SC03 Event: Maint.Feeder Run
(P11.02)
The sum of the times during which the mains voltage is on is greater than the time
P11.01 Maintenance Electric.
A message occurs after each expired time interval. The message may indicate ser-
vice work required.