EasyManuals Logo

Schenck process Intecont Tersus Beltweigher User Manual

Schenck process Intecont Tersus Beltweigher
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #150 background imageLoading...
Page #150 background image
Appendix
BV-H2464GB, 1234
- 144 -
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
Read the mean of the belt load q1(a) on the equipment and key it into the Linearization I1 parameters.
Key in the result of the formula q1(s) = q1(a) * Ms / Ma into the Linearization S1 parameters.
Where:
Ms: conveyed quantity of material in kg
Ma: quantity of material read on the equipment in kg
Repeat work processes 1 - 3 with increasingly large calibration weights for the other linearization points.