Parameters
BV-H2464GB, 1234
- 52 -
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
P02.06 [➙ 64]
Feeder Start OP
4241
P02.07 [➙ 64]
Counter 1 Unit ------- t
4230
P02.08 [➙ 64]
Pulse Length Total 0 ms
4231
P02.09 [➙ 64]
Counter 2 Unit ------- t
4232
P02.10 [➙ 64]
Counter 3 Unit ------- t
4233
P02.11 [➙ 64]
DO: Pulse Counter n/a
4239
P02.12 [➙ 64]
Totalizer Increment 10 kg
4254
P02.13 [➙ 64]
Z1-Numberstep Automatic
4255
03 - Calibration Data
Number: Name Default Customer Sys ID
P03.01 [➙ 67]
Belt Circuit No. 1
6145
P03.02 [➙ 67]
Belt Circuit Time 30 s
4353
P03.03 [➙ 67]
LC Characteristic Value 2.85 mV/V
4257
P03.04 [➙ 67]
LC Rated Capacity 220 kg
4258
P03.05 [➙ 67]
Effective Platform Length 1 m
4259
P03.06 [➙ 67]
Lever Ratio 1
4260
P03.07 [➙ 67]
Angle 0 Grad
4261
P03.08 [➙ 67]
Calibration Weight 50 kg
4354
04 - Calibrat. Results
Number: Name Default Customer Sys ID
P04.01 [➙ 68]
Nominal Belt Load 111.11 kg/m
6146
P04.02 [➙ 68]
Range Correction 1
4352
P04.03 [➙ 68]
Total Tare 0 kg/m
6147
P04.04 [➙ 68]
Basic Tare 0 kg/m
4355
P04.05 [➙ 68]
Tare Correction 0 kg/m
4356
P04.06 [➙ 68]
Belt Circuit No. 1000000 I/B
4357
05 - Analog Outputs
Number: Name Default Customer Sys ID
P05.01 [➙ 69]
AO: Actual Flow Rate AO
4388
P05.02 [➙ 69]
Flow Rate Offset 4 mA
4389
P05.03 [➙ 69]
Flow Rate Range 20 mA
4390
P05.04 [➙ 69]
AO: Belt Load n/a
4391