Pan Head
Sliding Strip
D A N G E R
Dirty, coated and / or ungreased contact surface
Incorrect current flow, injuries, damages
Clean and grease contact surfaces.
Pantograph raised PNEUMATICALLY.
Valve unit ADD responds, pantograph lowers.
NEVER raise pantograph pneumatically when replacing sliding strips.
After replacement of sliding strips: check if all pneumatic connections are connected
properly.
A T T E N T I O N
Improper replacement of sliding strips
Damages of pantograph and infrastructure
Always replace sliding strips (or collector strips) as pairs.
As a guide line to determine the intervals between visual inspections, please
consider the following:
Anticipated operating and wear life.
Extreme weather conditions (ice, snow, rain, sleet, etc.).
The sliding strips need to be checked for damage and wear at every visual
inspection:
The wear of both sliding strips should happen evenly.
If wear is uneven:
Check adjustment of parallel guide ( Chapter #14.12).
Check if pan head suspension or other parts of the pan head are damaged.