EasyManua.ls Logo

SCHUNK WBL 22.03 - Adjustment of Blow-Off Valve; Illustration 42: Adjustment of Blow off Valve

SCHUNK WBL 22.03
147 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Schunk Bahn- und Industrietechnik GmbH
Adjustment Procedures
SB-038483-EN.docx
94 / 147
Datum: 13.02.2018
SAP.Nr.10901359
Index: -
Adjustment of Blow-Off Valve
The pressure limiting valve (PLV1 Chapter #Appendix A) is properly adjusted by
the manufacturer. The blow-off valve must be adjusted if there is a change of
operating pressure or if the blow-off valve has been replaced.
Procedure:
1. Loosen check nut (2).
Adjust exhaust pressure 0,4 bar higher than the operating pressure of the
pressure regulation valve stage 2.
2. Adjustment is done by turning the adjustment screw (3).
Turning CLOCKWISE
Exhaust pressure INCREASES
Turning COUNTER-CLOCKWISE
Exhaust pressure DECREASES
3. Fix check nut.
Illustration 42: Adjustment of blow off valve
SB-027444_RS_Blatt 10
2
3

Table of Contents