8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 61
Operation via Ethernet (Ethernet interface)
Field "Measurement value
resolution"
Parameter Description
Distance
resolution
Choose resolution for the output value "Distance". The
measurement value is multiplied with the resolution. The
parameterdoesnotinuencethemeasurementvalue
displayed.
Read/Write access
• Read and write
Input value
• 0: 0.1 / 1: 0.125 / 2: 1.0 / 3: 10.0 / 4: 100.0 / 5: freRes
Factory setting
• 0.1 mm
Resolution
speed
Choose resolution for the output value "Speed". The
measurement value is multiplied with the resolution. The
parameterdoesnotinuencethemeasurementvalue
displayed.
Read/Write access
• Read and write
Input value
• 0: 0.1 / 1: 1.0 / 2: 10.0 / 3: 100.0 / 4: freRes
Factory setting
• 1 mm/s
Table 34: Page "Parameter settings" – eld "Measured value resolution"
Field"PROFINETIOconguration"
Parameter Description
StName Display station name
Read/Write access
• Read only
Factory setting
• dl100hf
Table 35: Page "Parameter settings" – eld "PROFINET IO conguration"
Field "MF1/MF2 activation"
Parameter Description
MF activation Activate and deactivate multifunction input and output MF1
and multifunction output MF2.
Read/Write access
• Read and write
Input value
• 0:o/1:on
Factory setting
• O
Table 36: Page "Parameter settings" – eld "MF1/MF2 activation"