Field"MF1Functionconguration" Requirements for the display
Parameter "MF1 activation": Option "Enable"
Parameter Description
Function Select function for multifunction input and output MF1.
Read/Write access
Read and write
Input value
0: Distance: Seepage63,eld"MF1,Thresholddistance
underow"
1: Velocity: Seepage64,eld"MF1,Thresholdvelocity
exceeded"
2: Service: Seepage64,eld"MF1,Serviceconguration"
3: Laser
4: Preset
Factory setting
Distance
Active condition Select level for the active condition for the multifunction input
and output MF1.
Read/Write access
Read and write
Input value
0: high / 1: low
Factory setting
Low
Table 37: Page “Parameter settings” – eld “MF1 Function conguration”