8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 89
PROFINET IO-interface
Module parameter "MF1"
Name Description
[MF1] Active
State
Select switching level for input and output MF1.
Value range
Low
High
Standard value
Low
[MF1 Distance]
threshold [mm]
Enter value of the distance threshold in "mm".
Value range
–300,000 ... 300,000 mm
Standard value
1,990 mm
[MF1 Distance]
Hysteresis [mm]
Enter hysteresis of the distance threshold in "mm".
Value range
1 ... 300,000 mm
Standard value
10 mm
[MF1 Speed]
Threshold
Enter speed threshold.
Value range
0 ... 15,000 mm/s
Standard value
5,000 mm/s
[MF1 Speed]
Mode
Select direction for detection in which the speed is exceeded.
Value range
Negative direction [–]
Positivedirection[+]
Bothdirections[+/–]
Standard value
Bothdirections[+/–]
[MF1 Service]
Laser Warning
The output switches when the laser module emits a warning.
Value range
O
On
Standard value
On