EasyManua.ls Logo

SICK DL100 Pro - PROFINET IO High Feature - Page 90

SICK DL100 Pro - PROFINET IO High Feature
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROFINET IO-interface
90 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
Module parameter "MF1"
(continued)
Name Description
[MF1 Service]
Level Warning
The output switches when the level is just within the
permissible range.
Value range
O
On
Standard value
On
[MF1 Service]
Temp. Warning
The output switches when the device temperature is within the
threshold range.
Value range
O
On
Standard value
On
[MF1 Service]
Plausib.
Warning
The output switches when the probability is high that the
measured value is not plausible.
Value range
O
On
Standard value
On
[MF1 Service]
Not Ready
The output switches when the device is not ready.
Value range
O
On
Standard value
On
[MF1 Service]
Heating Status
The output switches when the device heating is on.
Value range
O
On
Standard value
O

Table of Contents