8021823/126P/2018-12-17 • © SICK AG • Subject to change without notice 91
PROFINET IO-interface
Module parameter "MF2"
Name Description
MF2 Function Select function for the output MF2.
Value range
• [Output] Distance Threshold: Output switches when the
distance from module parameter "[MF2 Distance]
Threshold" was undercut.
• [Output] Speed Threshold: Output switches when the speed
from module parameter "[MF2 Distance] Speed" was
exceeded. The direction is determined in the module
parameter "[MF2 Speed] mode".
• [Output] Service: The output switches when at least one of
the service bits activated was set.
Standard value
• [Output] Service
[MF2] Active
State
Select switching level for input and output MF2.
Value range
• Low
• High
Standard value
• Low
[MF2 Distance]
Threshold [mm]
Enter value of the distance threshold in "mm".
Value range
• –300,000 ... 300,000 mm
Standard value
• 1,990 mm
[MF2 Distance]
Hysteresis [mm]
Enter hysteresis of the distance threshold in "mm".
Value range
• 1 ... 300,000 mm
Standard value
• 10 mm
[MF2 Speed]
Threshold
Enter speed threshold.
Value range
• 0 ... 15,000 mm/s
Standard value
• 5,000 mm/s
[MF2 Speed]
Mode
Select direction for detection in which the speed is exceeded.
Value range
• Negative direction [–]
• Positivedirection[+]
• Bothdirections[+/–]
Standard value
• Bothdirections[+/–]