Specifications
FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V2-1/2021-05 · © SICK Engineering GmbH 123
Subject to change without notice
Table 18 Volume conversion
Installation
Dimensions (W x H x D) See dimension drawings
Weight Depending on device version
Material in contact with
media
Low-temperature carbon steel, stainless steel, Duplex steel
Electrical connection
Voltage Flameproof pressurized electronics variant / electronics variant with terminal compartment in
increased type of protection:
Electrically isolated: 12 ... 24 V DC, ±10 %
Intrinsically safe electronics variant:
6 ... 16 V DC, ±10 %
PowerIn Technology™ with backup battery (2,400 mAh, 10.8 V),
optional for all electronics variants
Overvoltage category 1
Power input Typically 0.45 W ... 2.45 W
Dependent on selected electronics configuration
Components fitted (optional)
Pressure and temperature
sensor
Values measured for pressure and temperature are used to correct the meter body geometry and to
determine the current Reynolds number.
Conversion method PTZ (optional integrated)
Calculation method for
compressibility
SGERG88
AGA 8 Gross method 1
AGA 8 Gross method 2
AGA NX-19
AGA NX-19 mod.
NX-19 mod. (GOST)
GERG91 mod. (GOST)
Fixed value
GOST 3031.2-2015
Data archives 1 diagnostics archive (6,000 entries)
2 configurable measuring period archives (6,000 entries each)
Logbooks Event logbook (1,000 entries)
Parameter logbook (200 entries)
Metrology logbook (50 entries)