8.3 Measuring ranges
Table 19 Measuring ranges (metric)
Only the “Standard flow range according to MID" is applicable for device version FLOWSIC600-XT C.
The maximum gas velocity in the pipe is limited to 40 m/s in configurations with flow conditioner.
H[WHQGHG MID
PLQLPXP
IORZUDWH
[m³/h]
Standard
MID
PLQLPXP
IORZUDWH
[m³/h]
MID
WUDQVLWLRQ
IORZUDWH
[m³/h]
MID
PD[LPXP
IORZUDWH
[m³/h]
NRQ-MID
PD[LPXP
IORZUDWH [m³/h]
0HWHUVL]H
H[WHQGHG Q
min
Standard Q
min
DFF. ISO17089
Q
t
Standard
Q
max
e[WHQGHG
Maximal Q
max
V
max
[3]
V
t
DN80 (3") 5 8 40 650 1.000
61
2,5
DN100 (4") 8 13 65 1.000 1.600
63
2,5
DN150 (6") 16 20 100
3.000
52
1,7
DN200 (8") 20 32 160 4.000 4.500
44
1,6
DN250 (10“) 25 50 240
7.000
44
1,5
DN300 (12") 35 65 310 7.800 8.000
39
1,5
DN350 (14") 45 80 420 10.000 10.000
36
1,5
DN400 (16") 60 120 550 13.000 14.000
38
1,5
DN450 (18") 100 130 700 16.000 17.000
37
1,5
DN500 (20") 130 200 850 20.000 20.000
35
1,5
DN550 (22“) 150 260 1.000 24.000 24.000
35
1,5
DN600 (24") 180 320 1.200 28.000 32.000
39
1,5
DN650 (26“) 240 450 1.400 32.000 35.000
36
1,5
DN700 (28") 280 650 1.700 36.000 40.000
36
1,5
DN750 (30") 320 650 1.900 40.000 45.000
35
1,5
DN800 (32") 360 800 2.200 43.000 50.000
34
1,5
DN850 (34“) 400 900 2.500 47.000 55.000
33
1,5
DN900 (36") 450 1.000 2.800 51.000 66.000
36
1,5
DN950 (38") 500 1.100 3.100 56.000 70.000
34
1,5
DN1000 (40") 550 1.200 3.400 60.000 80.000
35
1,5
DN1050 (42") 600 1.300 3.800 65.000 85.000
34
1,5
DN1100 (44") 650 1.400 4.100 70.000 90.000
32
1,5
DN1150 (46") 700 1.500 4.500 72.000 95.000
34
1,5
DN1200 (48") 750 1.600 4.800 80.000 100.000
30
1,5
DN1300 (52") 900 1.700 5.600 90.000 110.000
28
1,5
DN1400 (56") 1.000 1.800 6.500 100.000 120.000
27
1,5
6WDQGDUGIORZUDWHUDQJHDFF0,'
([WHQGHGIORZUDWHUDQJHDFF0,'
m/s