104
8017171/115Z/V3-0/2019-01| SICKO P E R A T I N G I N S T R U C T I O N S | VISIC100SF
Subject to change without notice
SPECIFICATIONS
Display
LC display
Status LED
Green: Operation
Red: Malfunction
Yellow: Maintenance request
Input and operating Function buttons, single-line LC-Display
Dimensions (W x H x D)
266 mm x 159 mm x 117 mm (details, see dimensional
drawing, see “VISIC100SF dimensions (all units of measure-
ment in mm)”, page 98)
Weight 2.8 kg
Material, media contact Stainless steel 1.4571
Installation position
[1]
/installation
angle/swivel angle:
Wall assembly, vertical up to 45° wall inclination
Electric connection
Voltage: 18 ... 28 V DC, main power supply with
optional terminal box and/or TAD control unit
Power consumption: Max. 1 A
Power input:
Without heating: 5 W
With heating: 20 W
[1] Allowable enclosure tilt during operation
Terminal box
Protection class IP66 and IP6K9K
Dimensions
266 mm x 238 mm x 146 mm (details, see dimensional
drawing, see “Terminal box for VISIC100SF dimensions (all
units of measurement in mm)”, page 100)
Weight <2.8 kg
Material, media contact Stainless steel 1.4571
Electric connection
(optional)
Voltage: 85 ...264 V AC
Frequency: 45 ... 65 Hz
Power consumption: 0.1 A
Temperature class A: -40… +85 °C
Cross-section: 3 x 1.5 mm
2
TAD control unit
Protection class IP66
Dimensions
210 mm x 129 mm x 347 mm (details, see dimensional
drawing, see “Tunnel Adapter Device dimension (all units of
measurement in mm)”, page 99)
Weight 5 kg
Material, enclosure Stainless steel 1.4571
Electric connection
(optional)
Voltage: 88 ...264 V AC
Frequency: 47 ... 63 Hz
Power consumption: 15 VA
Optional I/O modules
Analog outputs
4 outputs: 4 ... 20 mA, electrically isolated (max. load
500 Ohm)

Table of Contents