24
8017171/115Z/V3-0/2019-01| SICKO P E R A T I N G I N S T R U C T I O N S | VISIC100SF
Subject to change without notice
INSTALLATION
3.4.3 Fitting the terminal box (optional)
Two terminal box versions
Fig. 16: Terminal box TB-A1 for connection
Fig. 17: Terminal box TB-A2 with 24V power supply unit and connection
Material required for terminal box assembly and installation
Material and drilling plan are identical to the VISIC100SF sensor, see “Assembly material”,
page 20 and see “Terminal box for VISIC100SF dimensions (all units of measurement in
mm)”, page 100.
Installing the terminal box
1 Determine the terminal box installation location according to the project planning.
2 Drill holes for the terminal box as shown in the drilling plan, see “Terminal box for
VISIC100SF dimensions (all units of measurement in mm)”, page 100.
3 Hammer in the M8 steel tie bar (from mounting kit).
4 Fit the terminal box.
5 Wiring, see “Terminal box wiring”, page 34.
6 Screw the cover on.
● Terminal box to reconnect cables provided
by the customer (e.g., rigid to flexible cable,
or cross-section adaptation).
● Terminal box with power supply unit and power
supply filter.
● Terminal box to reconnect cables provided by
the customer.