3 SYSTEM DESCRIPTION
38
8026362 / V1-0/2022-03|SICK
SUPPLEMENTARY OPERATING INSTRUCTIONS | VMS4100/5100
Subject to change without notice
3.7 Nominal operating conditions
The VMS4100 and VMS5100 multi-dimensional measurement systems can determine the
length, width, and height of the smallest enveloping cuboid for cubic measuring objects.
The VMS5100 is certified for the Singulated and Touching/Side-by-Side operating
modes in accordance with the Measuring Instruments Directive referenced in section 9.3
Compliance with EU directives.
3.7.1 Nominal value conditions for the “Singulated” and “Touching/Side-by-Side”operating modes (cubic only)
The following measuring ranges and scale values apply for the officially verifiable
VMS5100 in both operating modes:
Measuring range and scale interval value for VMS5100 - operating condition 1
(“Singulated”, “Touching/Side-by-Side” operating modes)
Min. Max. Scale value (d) Note
Length
50 mm
2.0"
5,500 mm
216.0"
5 mm
0.2"
Longest dimension of the
measuring object
Width
50 mm
2.0"
1,200 mm
47.0"
5 mm
0.2"
Dimension of the measuring
object orthogonal to the longest
dimension
Height
20 mm
1.0"
1,100 mm
43.0"
2 mm
0.1"
Maximum height of the
measuring object relative to
the transport belt surface
Tab. 1: Measuring range and scale interval value for VMS5100 (“Singulated”, “Touching/Side-by-
Side” - operating condition 1)
Measuring range and scale interval value for VMS5100 - operating condition 2
(“Singulated”, “Touching/Side-by-Side” operating modes)
Min. Max. Scale value (d) Note
Length
50 mm
2.0"
5,500 mm
216.0"
5 mm
0.2"
Longest dimension of the
measuring object
Width
50 mm
2.0"
1,200 mm
47.0"
5 mm
0.2"
Dimension of the measuring
object orthogonal to the longest
dimension
Height
50 mm
2.0"
1,100 mm
43.0"
5 mm
0.2"
Maximum height of the
measuring object relative to
the transport belt surface
Tab. 2: Measuring range and scale interval value for VMS5100 (“Singulated”, “Touching/Side-by-
Side” - operating condition 2)
Measuring range and scale interval value for VMS5100 - operating condition 3
(“Singulated”, “Touching/Side-by-Side” operating modes)
Min. Max. Scale value (d) Note
Length
100 mm
4.0"
5,500 mm
216.0"
10 mm
0.4"
Longest dimension of the
measuring object
Width
50 mm
2.0"
1,200 mm
47.0"
5 mm
0.2"
Dimension of the measuring
object orthogonal to the longest
dimension
Height
50 mm
2.0"
1,100 mm
43.0"
5 mm
0.2"
Maximum height of the
measuring object relative to
the transport belt surface
Tab. 3: Measuring range and scale interval value for VMS5100 (“Singulated”, “Touching/Side-by-
Side” - operating condition 3)

Table of Contents

Other manuals for SICK VMS4100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK VMS4100 and is the answer not in the manual?

SICK VMS4100 Specifications

General IconGeneral
BrandSICK
ModelVMS4100
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals