3.7 Nominal operating conditions
The VMS4100 and VMS5100 multi-dimensional measurement systems can determine the
length, width, and height of the smallest enveloping cuboid for cubic measuring objects.
The VMS5100 is certified for the Singulated and Touching/Side-by-Side operating
modes in accordance with the Measuring Instruments Directive referenced in section 9.3
Compliance with EU directives.
3.7.1 Nominal value conditions for the “Singulated” and “Touching/Side-by-Side”operating modes (cubic only)
The following measuring ranges and scale values apply for the officially verifiable
VMS5100 in both operating modes:
Measuring range and scale interval value for VMS5100 - operating condition 1
(“Singulated”, “Touching/Side-by-Side” operating modes)
Min. Max. Scale value (d) Note
Length
≥ 50 mm
≥ 2.0"
≤ 5,500 mm
≤ 216.0"
5 mm
0.2"
Longest dimension of the
measuring object
Width
≥ 50 mm
≥ 2.0"
≤ 1,200 mm
≤ 47.0"
5 mm
0.2"
Dimension of the measuring
object orthogonal to the longest
dimension
Height
≥ 20 mm
≥ 1.0"
≤ 1,100 mm
≤ 43.0"
2 mm
0.1"
Maximum height of the
measuring object relative to
the transport belt surface
Tab. 1: Measuring range and scale interval value for VMS5100 (“Singulated”, “Touching/Side-by-
Side” - operating condition 1)
Measuring range and scale interval value for VMS5100 - operating condition 2
(“Singulated”, “Touching/Side-by-Side” operating modes)
Min. Max. Scale value (d) Note
Length
≥ 50 mm
≥ 2.0"
≤ 5,500 mm
≤ 216.0"
5 mm
0.2"
Longest dimension of the
measuring object
Width
≥ 50 mm
≥ 2.0"
≤ 1,200 mm
≤ 47.0"
5 mm
0.2"
Dimension of the measuring
object orthogonal to the longest
dimension
Height
≥ 50 mm
≥ 2.0"
≤ 1,100 mm
≤ 43.0"
5 mm
0.2"
Maximum height of the
measuring object relative to
the transport belt surface
Tab. 2: Measuring range and scale interval value for VMS5100 (“Singulated”, “Touching/Side-by-
Side” - operating condition 2)
Measuring range and scale interval value for VMS5100 - operating condition 3
(“Singulated”, “Touching/Side-by-Side” operating modes)
Min. Max. Scale value (d) Note
Length
≥ 100 mm
≥ 4.0"
≤ 5,500 mm
≤ 216.0"
10 mm
0.4"
Longest dimension of the
measuring object
Width
≥ 50 mm
≥ 2.0"
≤ 1,200 mm
≤ 47.0"
5 mm
0.2"
Dimension of the measuring
object orthogonal to the longest
dimension
Height
≥ 50 mm
≥ 2.0"
≤ 1,100 mm
≤ 43.0"
5 mm
0.2"
Maximum height of the
measuring object relative to
the transport belt surface
Tab. 3: Measuring range and scale interval value for VMS5100 (“Singulated”, “Touching/Side-by-
Side” - operating condition 3)