COMMISSIONING 6
8026362 / V1-0/2022-03|SICK
Subject to change without notice
SUPPLEMENTARY OPERATING INSTRUCTIONS | VMS4100/5100
6.2.5 Logging on to device
▸
In the SOPAS toolbar, click on the icon with the three dots and select Device Login.
▸
Select the Authorized client user level and enter the default password client.
Click LOGIN to confirm.
The parameters that were previously grayed out on the tabs are now accessible.
6.3 Saving the parameters permanently
All parameters entered in SOPAS are transmitted to and executed on the connected
controller with the Immediate download option. However, the data is only saved
temporarily in the controller.
▸
Click on the Save parameters permanently icon in the SOPAS toolbar.
The configuration is transferred to the controller and saved there permanently.
This configuration is loaded whenever the controller is restarted.
▸
Click on the Save project button in the project window SOPAS toolbar.
▸
Choose a directory and file name and then confirm.
The settings are saved on the computer in a configuration file with the format *.spr.
NOTE! The settings within this file can be loaded subsequently (if required) and
transmitted to the controller.
Saving the
configuration in the
non-volatile memory
Saving the
configuration on the
computer