EasyManua.ls Logo

SICK VMS4100

SICK VMS4100
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SYSTEM DESCRIPTION 3
67
8026362 / V1-0/2022-03|SICK
Subject to change without notice
SUPPLEMENTARY OPERATING INSTRUCTIONS | VMS4100/5100
Fig. 62: Beam blockers for restricting the laser beams to the measuring range
Attach beam blockers to the mounting frame to restrict LMS4x21 laser beams to
the application space.
NOTE! Detection of people or objects located outside the measuring range is not
permitted. This would otherwise distort the measurement result.
3.9.4 Object requirements
Only cubic objects can be measured.
Dimensionally stable (not deformable)
Opaque surface (not transparent)
Non-reflective surface (no shiny or reflective surface)
The remission factor of the objects must be between 10% and max. 200%.
NOTE! Black objects with extremely low remission factor (< 10%) cannot be measured
with high accuracy.
Object color Remission factor [%]
Black cardboard 10
Blue 16
Red 75
White 98
Black with shiny tape 107
Beam restriction
Required object
properties
Remission factor

Table of Contents

Other manuals for SICK VMS4100

Related product manuals