05.05 Connectors and binectors
SIEMENS AG 6RX1700-0AD76 12-47
SIMOREG DC Master Operating Instructions
Binector Name, description Function
diag., Sheet
B7711
Receive data from the SIMOLINK board, word 7 bit 11 Z122
B7712
Receive data from the SIMOLINK board, word 7 bit 12 Z122
B7713
Receive data from the SIMOLINK board, word 7 bit 13 Z122
B7714
Receive data from the SIMOLINK board, word 7 bit 14 Z122
B7715
Receive data from the SIMOLINK board, word 7 bit 15 Z122
B7800
Receive data from the SIMOLINK board, word 8 bit 0 Z122
B7801
Receive data from the SIMOLINK board, word 8 bit 1 Z122
B7802
Receive data from the SIMOLINK board, word 8 bit 2 Z122
B7803
Receive data from the SIMOLINK board, word 8 bit 3 Z122
B7804
Receive data from the SIMOLINK board, word 8 bit 4 Z122
B7805
Receive data from the SIMOLINK board, word 8 bit 5 Z122
B7806
Receive data from the SIMOLINK board, word 8 bit 6 Z122
B7807
Receive data from the SIMOLINK board, word 8 bit 7 Z122
B7808
Receive data from the SIMOLINK board, word 8 bit 8 Z122
B7809
Receive data from the SIMOLINK board, word 8 bit 9 Z122
B7810
Receive data from the SIMOLINK board, word 8 bit 10 Z122
B7811
Receive data from the SIMOLINK board, word 8 bit 11 Z122
B7812
Receive data from the SIMOLINK board, word 8 bit 12 Z122
B7813
Receive data from the SIMOLINK board, word 8 bit 13 Z122
B7814
Receive data from the SIMOLINK board, word 8 bit 14 Z122
B7815
Receive data from the SIMOLINK board, word 8 bit 15 Z122
B7900
Receive data from the SIMOLINK board, word 9 bit 0 Z122
B7901
Receive data from the SIMOLINK board, word 9 bit 1 Z122
B7902
Receive data from the SIMOLINK board, word 9 bit 2 Z122
B7903
Receive data from the SIMOLINK board, word 9 bit 3 Z122
B7904
Receive data from the SIMOLINK board, word 9 bit 4 Z122
B7905
Receive data from the SIMOLINK board, word 9 bit 5 Z122
B7906
Receive data from the SIMOLINK board, word 9 bit 6 Z122
B7907
Receive data from the SIMOLINK board, word 9 bit 7 Z122
B7908
Receive data from the SIMOLINK board, word 9 bit 8 Z122
B7909
Receive data from the SIMOLINK board, word 9 bit 9 Z122
B7910
Receive data from the SIMOLINK board, word 9 bit 10 Z122
B7911
Receive data from the SIMOLINK board, word 9 bit 11 Z122
B7912
Receive data from the SIMOLINK board, word 9 bit 12 Z122
B7913
Receive data from the SIMOLINK board, word 9 bit 13 Z122
B7914
Receive data from the SIMOLINK board, word 9 bit 14 Z122
B7915
Receive data from the SIMOLINK board, word 9 bit 15 Z122
Process data exchange with 2
nd
CB
B8030
Fault delay timeout for 2
nd
CB - maintained signal Z111
B8031
Fault delay timeout for 2
nd
CB - 1s pulse Z111
B8035
Telegram failure timeout for 2
nd
CB [SW 1.9 and later] Z111
Process data exchange with 2
nd
CB
B8100
Receive data from 2
nd
CB, word 1, bit 0 Z111
B8101
Receive data from 2
nd
CB, word 1, bit 1 Z111
B8102
Receive data from 2
nd
CB, word 1, bit 2 Z111
B8103
Receive data from 2
nd
CB, word 1, bit 3 Z111
B8104
Receive data from 2
nd
CB, word 1, bit 4 Z111
B8105
Receive data from 2
nd
CB, word 1, bit 5 Z111

Table of Contents