6.6.2.3 XR-300M EEC product group
Table 6-11 100 to 240 V AC voltage
Device Device version (power supply) 100 to 240 V voltage
Redundant Single
XR324-4M EEC 1 x 100 to 240 V AC / 60 to 250 V DC - ●
2 x 100 to 240 V AC / 60 to 250 V DC ● -
6.6.2.4 XR-300M PoE product group
Table 6-12 100 to 240 V AC voltage
Device Device version
(power supply)
100 to 240 V voltage
Redundant Single
XR324-4M PoE 1 x 100 to 240 V AC - ●
6.6.2.5 Fitting the connector for 100 to 240 V AC
WARNING
Danger from line voltage
If used with cables with more than two wires, correct functioning of the connector casing
cannot be guaranteed because the two halves of the connector casing can come apart. If this
occurs, you will also not be able to connect all the wires in the connector. Open wire ends may
be dangerous due to line voltage.
Use only two-wire cables.
Connecting
6.6 Power supply
SCALANCE X-300
136 Operating Instructions, 11/2019, A5E01113043-24