EasyManua.ls Logo

Siemens SCALANCE X-300 Series - MM992-2 CU Product Characteristics

Siemens SCALANCE X-300 Series
312 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
[Device labeling in square brackets]
Note
Installation of the XR-300M, XR-300M PoE and XR-300M EEC
Only the lower slots may be equipped with the MM991-2P.
XR-300M: Maximum 6 modules in slots 7 to 12
XR-300M PoE, XR-300M EEC: Maximum 2 modules in slots 3 and 4
The slot above an MM991-2P may only be used as follows:
Without media module
With media module MM992-2CUC or MM992-2CU
Example XR-300M: If the MM991-2P is plugged into slot 8, an MM992-2CUC may be used in
slot 2.
See also table: "Operating temperature with media module MM991-2P"
4.4.8.8 MM992-2CU product characteristics
Possible attachments
The MM992-2CU media module has the following:
2 x 10/100/1000 Mbps, RJ-45 port electrical without securing collar
Figure 4-33 MM992-2CU [9922SA]
[Device labeling in square brackets]
Note
For connection to electrical networks note the information in Appendix A.1 and A.2.
Description of the device
4.4 Product properties and device views
SCALANCE X-300
Operating Instructions, 11/2019, A5E01113043-24 79