P1 P2
P3 P4
P5 P6
P7 P8
1
P1 P2
2
P1 P2
P9 P10
P11 P12
P13 P14
P15 P16
3
P1 P2
4
P1 P2
1 2 3
1 Gbit/s
1 Gbit/s
Figure 8-5 Block architecture of the XR324‑4M
8.8.5 Other properties
Switching properties
Max. number of learnable addresses 8000
Aging time 30 sec
Switching technique Store and forward
Latency 5 μs
Reconfiguration times for redundancy mechanisms
Redundancy mechanism Reconfiguration times
HRP 300 ms
Standby link 300 ms
MRP 200 ms
Mean time between failure (MTBF)
The value in the following table applies to the basic device without media modules.
MTBF > 15 years
1)
1)
This value applies at 40 °C.
In the calculation of the MTBF of a modular switch, the standard parts count applies; in other
words, the reciprocals of all component failure rates are added.
The reciprocal of this total id the MTBF of the entire assembly.
07%)
WRWDO
07%)
EDVLFGHYLFH
07%)
PRGXOHQ
07%)
PRGXOH
Technical specifications
8.8 XR-300M PoE technical specifications
SCALANCE X-300
200 Operating Instructions, 11/2019, A5E01113043-24