Table 11-3 Overview of the approvals
Device Variant c‑UL‑us
Inf. Tech.
Eq.
c‑UL‑us
for Hazard‐
ous Loca‐
tions
1)
c‑UL‑us
Ind. Cont.
Eq.
FM
1)
C‑TICK CE ATEX95
Zone 2
1)
XR324-12
M
2 x 24 VDC,
Data cable
outlet on
front
1 x 100 to
240 VAC,
Data cable
outlet on
front
2 x 24 VDC
Data cable
outlet at rear
1 x 100 to
240 VAC,
data cable
outlet at rear
1
For temperature information "T.." or the maximum ambient temperature "Ta:..", refer to the type plate.
11.3.1.5 XR-300M mechanical stability (in operation)
Device:
SCALANCE
(Variant) IEC 60068-2-6 vibration IEC 60068-2-27 shock IEC 60068-2-6 vibration *)
10 – 58 Hz: 0.15 mm
58 – 500 Hz: 1 g
1 octave/min,
10 cycles
15 g, 11 ms duration
6 shocks per axis
5 – 8.51 Hz: 7 mm
8.51 – 500 Hz: 1 g
1 octave/min,
10 cycles
XR324-12M ( 2 x DC data cable outlet on
front)
XR324-12M (1 x 100...240 VAC, data cable
outlet on front)
XR324-12M ( 2 x 24 VDC data cable outlet at
rear)
XR324-12M (1 x 100 to 240 VAC, data cable
outlet at rear)
*) Note: When rack mounted with 4 securing points
Certifications and approvals
11.3 Product group XR-300M
SCALANCE X-300
268 Operating Instructions, 11/2019, A5E01113043-24