8.9.3 Cable lengths
Copper cables
Table 8-104 Permitted cable lengths (copper cable - Fast Ethernet)
Media module Cable Permitted cable length
MM992-2CUC
MM992-2CUC (C)
MM992-2CU
MM992-2M12 (C)
MM992-2VD (without
VD)
1)
IE TP torsion cable with
IE FC Outlet RJ-45 + 10 m TP cord
0 to 45 m
+ 10 m TP cord
IE TP torsion cable
with IE FC RJ-45 Plug 180
0 to 55 m
IE FC TP marine/trailing/flexible cable with
IE FC Outlet RJ-45 + 10 m TP cord
0 to 75 m
+ 10 m TP cord
IE FC TP marine/trailing/ flexible cable with
IE FC RJ-45 Plug 180
0 to 85 m
IE FC TP standard cable with
IE FC Outlet RJ-45 + 10 m TP cord
0 to 90 m
+ 10 m TP cord
IE FC TP standard cable
with IE FC RJ-45 plug 180
0 to 100 m
MM992-2VD (with VD)
2)
IE FC TP standard cable GP 4X2 (24
AWG) with IE FC RJ-45 plug 4x2
0 to 500 m at 100 Mbps
IE FC TP standard cable GP 2x2
with IE FC RJ-45 plug 2x2
0 to 300 m at 100 Mbps.
IE FC TP standard cable GP 2x2
with IE FC RJ-45 plug 2x2
300 to 500 m at 10 Mbps
PROFIBUS FC standard cable GP
with IE FC RJ-45 plug 4x2
100 to 1000 m at 10 Mbps
PROFIBUS FC standard cable GP
with IE FC RJ-45 plug 4x2
0 to 100 m at 100 Mbps.
1)
The VD mode (Variable Distance) is turned off.
2)
The VD mode (Variable Distance) is turned on.
Technical specifications
8.9 MM900 technical specifications
SCALANCE X-300
Operating Instructions, 11/2019, A5E01113043-24 207

Table of Contents

Other manuals for Siemens SCALANCE X-300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-300 Series and is the answer not in the manual?

Siemens SCALANCE X-300 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-300 Series
CategorySwitch
LanguageEnglish

Related product manuals