EasyManua.ls Logo

Siemens SCALANCE X-300 Series

Siemens SCALANCE X-300 Series
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical specifications
8
8.1 Overview of operating temperatures for SCALANCE X-300
Operating temperature depending on the media modules used
The information applies to media modules with product version 2 (PV2):
Type Installation
location
Without media
module
MM992-2CUC
MM992-2CU
MM991-2
MM991-2LD
MM991-2 (SC)
MM991-2LD (SC)
MM992-2
MM992-2LD
MM991-2LH+ (SC)
MM992-2LH
MM992-2LH+
MM992-2ELH
Media module
MM992-2SFP
with SFP trans‐
ceiver
SFP991-1
SFP991-1LD
SFP992-1
SFP992-1LD
Media module
MM992-2SFP
with SFP trans‐
ceiver
SFP991-1LH+
SFP992-1LH
SFP992-1+
SFP992-1LH+
SFP992-1ELH
X-300M Horizontal -40 °C to +70 °C -40 °C to +60 °C
Vertical -40 °C to +50 °C
X-300M
PoE
Horizontal -40 °C to +60 °C -40 °C to +50 °C -40 °C to +60 °C -40 °C to +50 °C
Vertical -40 °C to +45 °C
XR-300M Horizontal Not possible
(fully modular
device)
-40 °C to +70 °C Maximum 2
modules in slots 11
and 12:
-40 °C to +60 °C
With more than 2
modules or other
slot assignment:
-40 °C to +50 °C
-40 °C to +60 °C
Maximum 2 mod‐
ules in slots 11
and 12:
-40 °C to +60 °C
With more than 2
modules or other
slot assignment:
-40 °C to +50 °C
Vertical Not possible
(fully modular
device)
-40 °C to +50 °C
XR-300M
PoE
Horizontal -40 °C to +60 °C Maximum 2
modules in slots 11
and 12:
-40 °C to +60 °C
With more than 2
modules or other
slot assignment:
-40 °C to +50 °C
-40 °C to +60 °C Maximum 2 mod‐
ules in slots 11
and 12:
-40 °C to +60 °C
With more than 2
modules or other
slot assignment:
-40 °C to +50 °C
Vertical -40 °C to +50 °C
SCALANCE X-300
Operating Instructions, 11/2019, A5E01113043-24 151