11.5.1.4 XR-300M EEC mechanical stability (in operation)
The devices of the SCALANCE XR-300M EEC product group meet the following standards
(prerequisite: rack mounted with 4 securing points):
IEC 60068-2-6
(vibrations during transportation and operation)
Test parameters:
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
1 octave/min, 20 sweeps
IEC 60068-2-27
(shocks during operation)
Test parameters:
15 g, 11 ms duration
6 shocks per axis
IEC 60068-2-6
(vibrations during transportation)
Test parameters:
10 – 58 Hz: 0.075 mm
85 – 150 Hz: 1 g
1 octave/min, 20 sweeps
11.6 Product group X-300M PoE
11.6.1 Approvals
11.6.1.1 X-300M PoE approvals, certificates
Approvals issued
Note
Issued approvals on the type plate of the device
The specified approvals apply only when the corresponding mark is printed on the product. You
can check which of the following approvals have been granted for your product by the markings
on the type plate.
Approvals for shipbuilding are not printed on the device type plate.
Certifications and approvals
11.6 Product group X-300M PoE
SCALANCE X-300
280 Operating Instructions, 11/2019, A5E01113043-24

Table of Contents

Other manuals for Siemens SCALANCE X-300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE X-300 Series and is the answer not in the manual?

Siemens SCALANCE X-300 Series Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE X-300 Series
CategorySwitch
LanguageEnglish

Related product manuals