IECEx
The SIMATIC NET products meet the requirements of explosion protection according to IECEx.
IECEx classification:
Ex nA IIC T4 Gc
DEK 14.0025X
The products meet the requirements of the following standards:
IEC 60079-15 : 2010 (Explosive atmospheres - Part 15: Equipment protection by type of
protection "n"
IEC 60079-0 : 2011 (Explosive atmospheres - Part 0: Equipment - General requirements)
Note
Only variants with 24 VDC power supply meet the requirements of this approval.
IEC 61850‑3 (EN55022 / CISPR22 CLASS A)
The product meets the requirements of the standard IEC 61850‑3
(EN55022 / CISPR22 CLASS A).
IEEE 1613
The product meets the requirements of the standard IEEE 1613 CLASS 1 (electrical ports) or
IEEE 1613 CLASS 2 (optical ports).
FM
The product meets the requirements of the standards:
Factory Mutual Approval Standard Class Number 3611
FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and
Non Incendive / Class I / Zone 2 / Group IIC / T4
Note
Only variants with 24 VDC power supply meet the requirements of this approval.
C-Tick
The product meets the requirements of the AS/NZS 2064 standard (Class A).