Configuring with Web Based Management
5.4 The "System" menu
SCALANCE XB-200 Web Based Management
106 Configuration Manual, 04/2015, C79000-G8976-C360-02
●
Last Synchronization Mechanism
This box displays how the last time-of-day synchronization was performed. The following
methods are possible:
– Not set
The system time was not set.
– Manual
Manual time setting
– SNTP
Automatic time-of-day synchronization with SNTP
– NTP
Automatic time-of-day synchronization with NTP
– SIMATIC
Automatic time-of-day synchronization using the SIMATIC time frame
●
In this box, enter the time zone you are using in the format "+/- HH:MM". The time zone
relates to UTC standard world time.
●
Enter the IP address of the NTP server.
●
Enter the port of the NTP server.
The following ports are possible:
– 123 (standard port)
– 1025 to 36564
●
Here, enter the interval between two-time queries. In this box, you enter the query interval
in seconds. Possible values are 64 to 1024 seconds.
1. Click the "NTP Client" check box to enable the automatic time setting using NTP.
2. Enter the necessary values in the following boxes:
– Time zone
– NTP server IP address
– NTP server port
– Query interval
3. Click the "Set Values" button.