Configuring with Web Based Management
5.4 The "System" menu
SCALANCE XB-200 Web Based Management
106 Configuration Manual, 04/2015, C79000-G8976-C360-02
Last Synchronization Mechanism
This box displays how the last time-of-day synchronization was performed. The following
methods are possible:
Not set
The system time was not set.
Manual
Manual time setting
SNTP
Automatic time-of-day synchronization with SNTP
NTP
Automatic time-of-day synchronization with NTP
SIMATIC
Automatic time-of-day synchronization using the SIMATIC time frame
Time Zone
In this box, enter the time zone you are using in the format "+/- HH:MM". The time zone
relates to UTC standard world time.
NTP Server IP Address
Enter the IP address of the NTP server.
NTP Server Port
Enter the port of the NTP server.
The following ports are possible:
123 (standard port)
1025 to 36564
Poll Interval(s)
Here, enter the interval between two-time queries. In this box, you enter the query interval
in seconds. Possible values are 64 to 1024 seconds.
Procedure
1. Click the "NTP Client" check box to enable the automatic time setting using NTP.
2. Enter the necessary values in the following boxes:
Time zone
NTP server IP address
NTP server port
Query interval
3. Click the "Set Values" button.

Table of Contents

Other manuals for Siemens SCALANCE XB-200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XB-200 and is the answer not in the manual?

Siemens SCALANCE XB-200 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XB-200
CategorySwitch
LanguageEnglish

Related product manuals