Configuring with Web Based Management
5.4 The "System" menu
SCALANCE XB-200 Web Based Management
122 Configuration Manual, 04/2015, C79000-G8976-C360-02
5.4.17
EtherNet/IP
EtherNet/IP
On this page, you configure the mode of EtherNet/IP.
Description of the displayed boxes
The page contains the following boxes:
EtherNet/IP Mode
Shows whether EtherNet/IP is enabled ("On") or disabled ("Off").
EtherNet/IP Mode for next boot
Set whether EtherNet/IP will be enabled ("On") or disabled ("Off") after the next device
restart.
Note
PNIO AR Status
If a PROFINET connection is established; in other words the PNIO AR status is "Online",
you cannot enable EtherNet/IP.