EasyManua.ls Logo

Siemens SCALANCE XB-200 - RADIUS Client

Siemens SCALANCE XB-200
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring with Web Based Management
5.6 The "Security" menu
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02
177
5.6.2.2
RADIUS client
Authentication over an external server
The concept of RADIUS is based on an external authentication server. An end device can
only access the network after the device has verified the logon data of the device with the
authentication server. Both the end device and the authentication server must support the
EAP protocol (Extensive Authentication Protocol).
Each column of the table contains access data for one server. In the search order, the
primary server is queried first. If the primary server cannot be reached, secondary servers
are queried in the order in which they are entered.
If no server responds, there is no authentication. The client has no access to the network
although a link is indicated at the port.
Description of the displayed boxes
The table has the following columns:
Select
Select the row you want to delete.
Server Address
Enter the IP address of the server here.
Server Port
Here, enter the input port on the RADIUS server. As default, input port 1812 is set. The
range of values is 1 to 65535.
Shared Secret
Enter your access ID here.
Shared Secret Conf.
Enter your access ID again as confirmation.
Max. Retrans.
Here, enter the maximum number of query attempts before another configured RADIUS
server is queried or the logon counts as having failed. As default, 3 is set. The range of
values is 1 to 254.