Configuring with Web Based Management
5.5 The "Layer 2" menu
SCALANCE XB-200 Web Based Management
136 Configuration Manual, 04/2015, C79000-G8976-C360-02
●
Select the VLAN ID from the drop-down list. Only VLAN IDs defined on the "VLAN >
General" page can be selected.
If a received frame does not have a VLAN tag, it has a tag with the VLAN ID specified
here added to it and is sent according to the rules at the port.
●
Specify which types of frames will be accepted. The following alternatives are possible:
– Tagged Frames Only
The device discards all untagged frames. Otherwise, the forwarding rules apply
according to the configuration.
– All
The device forwards all frames.
●
Specify whether the VID of received frames is evaluated
You have the following options:
– Enabled
The VLAN ID of received frames decides whether they are forwarded: To forward a
VLAN tagged frame, the receiving port must be a member in the same VLAN. Frames
from unknown VLANs are discarded at the receiving port.
– Disabled
All frames are forwarded.
1. In the row of the port to be configured, click on the relevant cell in the table to configure it.
2. Enter the values to be set in the input boxes as follows.
3. Select the values to be set from the drop-down lists.
4. Click the "Set Values" button.
The device provides the option of simultaneously channeling incoming or outgoing data
streams via other interfaces for analysis or monitoring. This has no effect on the monitored
data streams. This procedure is known as mirroring. In this menu section, you enable or
disable mirroring and set the parameters.
Mirroring a port means that the data traffic at a port (mirrored port) of the IE switch is copied
to another port (monitor port). You can mirror one or more ports to a monitor port.