Configuring with Web Based Management
5.3 The "Information" menu
SCALANCE XB-200 Web Based Management
56 Configuration Manual, 04/2015, C79000-G8976-C360-02
5.3.7.2
Ring redundancy
Information on ring redundancy
On this tab, you obtain information about the status of the device in terms of ring
redundancy. The text boxes on this page are read-only.
Description of the displayed values
The following boxes are displayed:
Redundancy Function
The "Redundancy Function" box shows the role of the device within the ring:
No Ring Redundancy (off)
The IE switch is operating without redundancy function.
HRP Client
The IE switch is operating as an HRP client.
HRP Manager
The IE switch is operating as an HRP manager.
MRP Client
The IE switch is operating as an MRP client.
MRP Manager
The IE switch is operating as an MRP manager.
Note
MRP configuration in STEP 7
If you set the role "Manager (Auto)" or "Manager" for the device in STEP 7, in both
cases, "MRP Manager" is displa
yed on this WBM page. In the display in the CLI, a
distinction is made between the two roles.