Configuring with Web Based Management
5.3 The "Information" menu
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02
55
Path Cost
This parameter is used to calculate the path that will be selected. The path with the
lowest value is selected. If several ports of a device have the same value, the port with
the lowest port number is selected.
If the value in the "Cost Calc" field is "0", the automatically calculated value is displayed.
Otherwise, the value of the "Cost Calc" field is displayed.
The calculation of the path costs is largely based on the transmission speed. The higher
the achievable transmission speed is, the lower the value of the path costs.
Typical values for path costs with rapid spanning tree:
10,000 Mbps = 2,000
1000 Mbps = 20,000
100 Mbps = 200,000
10 Mbps = 2,000,000
Edge Type
Shows the type of the connection. The following values are possible:
Edge Port
There is an end device at this port.
No Edge Port
There is a spanning tree or rapid spanning tree device at this port.
P.t.P. Type
Shows the type of point-to-point link. The following values are possible:
P.t.P.
With half duplex, a point-to-point link is assumed.
Shared Media
With a full duplex connection, a point-to-point link is not assumed.