Configuring with Web Based Management
5.4 The "System" menu
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02
117
5.4.15
Fault monitoring
5.4.15.1
Power Supply
Settings for monitoring the power supply
Configure whether or not the power supply should be monitored by the messaging system.
Depending on the hardware variant there are one or two power connectors (Line 1 / Line 2).
With a redundant power supply, configure the monitoring separately for each individual feed-
in line.
A fault is then signaled by the message system when there is no power on one of the
monitored lines (Line 1 or Line 2) or when the voltage is too low.
Note
You will find the permitted operating voltage limits in the operating instructions of the device.
A fault causes the fault LED on the device to light up and, depending on the configuration,
can trigger a trap, an e-mail, or an entry in the event log table.
Procedure
1. Click the check box in front of the line name you want to monitor to enable or disable the
monitoring function.
2. Click the "Set Values" button.