Configuring with Web Based Management
5.4 The "System" menu
SCALANCE XB-200 Web Based Management
116 Configuration Manual, 04/2015, C79000-G8976-C360-02
OperState
Displays the current operational status. The operational status depends on the configured
"Status" and the "Link". The available options are as follows:
Up
You have configured the status "enabled" for the port and the port has a valid
connection to the network.
Down
You have configured the status "disabled" or "Link down" for the port or the port has
no connection.
Link
Shows the connection status to the network. The available options are as follows:
Up
The port has a valid link to the network, a link integrity signal is being received.
Down
The link is down, for example because the connected device is turned off.
Changing the port configuration
Click the appropriate box to change the configuration.
Note
Optical ports only work with the full duplex mode and at maximum transmission rate. As a
result, the following settings cannot be made for optical ports:
Automatic configuration
Transmission speed
Transmission technique
Note
With various automatic functions, the device prevents or reduces the effect on other ports
and priority classes (Class of Service) if a port is overloaded. This can mean that frames are
discarded even when flow control is enabled.
Port overload
occurs when the device receives more frames than it can send, for example as
the result of different transmission speeds.
Steps in configuration
1. Change the settings according to your configuration.
2. Click the "Set Values" button.